WV-MIB DEFINITIONS ::= BEGIN IMPORTS OBJECT-TYPE, MODULE-IDENTITY, enterprises, Integer32 FROM SNMPv2-SMI DisplayString FROM SNMPv2-TC; webvoltmeter MODULE-IDENTITY LAST-UPDATED "201303152346Z" ORGANIZATION "Tycon Power Systems" CONTACT-INFO "" DESCRIPTION "Web Voltmeter custom MIBs" ::= { enterprises 3 } -- Web Voltmeter tycon OBJECT IDENTIFIER ::= { enterprises 17095 } product OBJECT IDENTIFIER ::= { tycon 1 } control OBJECT IDENTIFIER ::= { tycon 3 } ON-OFF ::= INTEGER { ON(1), OFF(0) } name OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "" ::= { product 1 } version OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "" ::= { product 2 } builddate OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "" ::= { product 3 } -- Controls relay 1 relay1 OBJECT-TYPE SYNTAX INTEGER { OFF(0), ON(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "Relay 1 control" ::= { control 1 } relay2 OBJECT-TYPE SYNTAX INTEGER { OFF(0), ON(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "Relay 2 control" ::= { control 2 } relay3 OBJECT-TYPE SYNTAX INTEGER { OFF(0), ON(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "Relay 3 control" ::= { control 3 } relay4 OBJECT-TYPE SYNTAX INTEGER { OFF(0), ON(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "Relay 4 control" ::= { control 4 } volt1 OBJECT-TYPE SYNTAX DisplayString (SIZE(10)) MAX-ACCESS read-only STATUS current DESCRIPTION "Volt 1 reading" ::= { control 5 } volt2 OBJECT-TYPE SYNTAX DisplayString (SIZE(10)) MAX-ACCESS read-only STATUS current DESCRIPTION "Volt 2 reading" ::= { control 6 } volt3 OBJECT-TYPE SYNTAX DisplayString (SIZE(10)) MAX-ACCESS read-only STATUS current DESCRIPTION "Volt 3 reading" ::= { control 7 } volt4 OBJECT-TYPE SYNTAX DisplayString (SIZE(10)) MAX-ACCESS read-only STATUS current DESCRIPTION "Volt 4 reading" ::= { control 8 } amp1 OBJECT-TYPE SYNTAX DisplayString (SIZE(10)) MAX-ACCESS read-only STATUS current DESCRIPTION "Current 1 reading in Amps" ::= { control 9 } amp2 OBJECT-TYPE SYNTAX DisplayString (SIZE(10)) MAX-ACCESS read-only STATUS current DESCRIPTION "Current 2 reading in Amps" ::= { control 10 } amp3 OBJECT-TYPE SYNTAX DisplayString (SIZE(10)) MAX-ACCESS read-only STATUS current DESCRIPTION "Current 3 reading in Amps" ::= { control 11 } amp4 OBJECT-TYPE SYNTAX DisplayString (SIZE(10)) MAX-ACCESS read-only STATUS current DESCRIPTION "Current 4 reading in Amps" ::= { control 12 } temp1 OBJECT-TYPE SYNTAX DisplayString (SIZE(10)) MAX-ACCESS read-only STATUS current DESCRIPTION "Temperature on board in Celsius" ::= { control 13 } temp2 OBJECT-TYPE SYNTAX DisplayString (SIZE(10)) MAX-ACCESS read-only STATUS current DESCRIPTION "Temperature measured by external sensor in Celsius" ::= { control 14 } END